Posts by Category

How to 9
KBase 1
SOP 1
BIOS 3
BMC 2
Firmware 2
Hardware 4
IPMI 3
Liquid Cooling 1
OpenBMC 1
Redfish 1

How to

How to Reset OpenBMC Password

1 minute read

This article explains how to reset the MiTAC R1520G6, R2520G6, and G4520G6 OpenBMC password using ipmitool, covering both remote reset (for when you still ha...

How to Reset B8056 Power-On Hours

1 minute read

This article explains how to reset the Power-On Hours (POH) counter on the B8056 platform using a Linux script that wraps an ipmitool command.

How to Reset BMC Password

1 minute read

This article explains how to reset the BMC password using ipmitool, covering both remote reset (when you still have network access to the BMC) and local rese...

How to Disable B8016 CPU iGPU Function

1 minute read

This article provides a solution for disabling the CPU integrated GPU (iGPU) on the B8016 platform via BIOS settings, addressing scenarios where the AMD Rade...

How to Adjust S8016AGM2NR System FAN Speed

2 minute read

This article explains how to manually adjust the system FAN speed on the S8016AGM2NR using IPMI raw commands, addressing scenarios where the default BMC fan ...

Back to Top ↑

KBase

Back to Top ↑

SOP

BOYD RAA32-10U21 CDU Refill SOP

3 minute read

Standard operating procedure for refilling coolant, venting air, and verifying dual-pump redundancy on the BOYD RAA32-10U21 CDU.

Back to Top ↑

BIOS

How to Disable B8016 CPU iGPU Function

1 minute read

This article provides a solution for disabling the CPU integrated GPU (iGPU) on the B8016 platform via BIOS settings, addressing scenarios where the AMD Rade...

Back to Top ↑

BMC

How to Reset B8056 Power-On Hours

1 minute read

This article explains how to reset the Power-On Hours (POH) counter on the B8056 platform using a Linux script that wraps an ipmitool command.

How to Reset BMC Password

1 minute read

This article explains how to reset the BMC password using ipmitool, covering both remote reset (when you still have network access to the BMC) and local rese...

Back to Top ↑

Firmware

Back to Top ↑

Hardware

How to Disable B8016 CPU iGPU Function

1 minute read

This article provides a solution for disabling the CPU integrated GPU (iGPU) on the B8016 platform via BIOS settings, addressing scenarios where the AMD Rade...

How to Adjust S8016AGM2NR System FAN Speed

2 minute read

This article explains how to manually adjust the system FAN speed on the S8016AGM2NR using IPMI raw commands, addressing scenarios where the default BMC fan ...

Back to Top ↑

IPMI

How to Reset B8056 Power-On Hours

1 minute read

This article explains how to reset the Power-On Hours (POH) counter on the B8056 platform using a Linux script that wraps an ipmitool command.

How to Reset BMC Password

1 minute read

This article explains how to reset the BMC password using ipmitool, covering both remote reset (when you still have network access to the BMC) and local rese...

How to Adjust S8016AGM2NR System FAN Speed

2 minute read

This article explains how to manually adjust the system FAN speed on the S8016AGM2NR using IPMI raw commands, addressing scenarios where the default BMC fan ...

Back to Top ↑

Liquid Cooling

BOYD RAA32-10U21 CDU Refill SOP

3 minute read

Standard operating procedure for refilling coolant, venting air, and verifying dual-pump redundancy on the BOYD RAA32-10U21 CDU.

Back to Top ↑

OpenBMC

How to Reset OpenBMC Password

1 minute read

This article explains how to reset the MiTAC R1520G6, R2520G6, and G4520G6 OpenBMC password using ipmitool, covering both remote reset (for when you still ha...

Back to Top ↑

Redfish

Back to Top ↑